The control panels are feature-rich and designed to fully meet the needs of installations up to 16 wired zones. S16cmR or S16emR is an ideal cost-effective solution for alarm monitoring companies.
Specification
On-board wired zones 5/10 (doubling)
2-wire smoke detector input 1
On-board wireless zones - none
Maximum zones in system 16
On-board PGM 3
Maximum PGM in system 16
User + installer codes 31+1
Duress code Yes
Defaulting user code Yes
Key switch zone Yes
Partitions 4
"Shared" partition (common area) Yes
System timers 16
Maximum keypads/modules in system 3
Keypad compatibility All SECOLINK keypads
Event log buffer 256 (with keypad 512)
Interface with transmitters and communicators of other manufacturers -
Data bus protocol KRBUS
"Roller" detector type Yes
"Vibration" detector type Yes
Notifications to the user, reporting to CMS using the user's SIM card
Number of recipients for SMS, voice clip messaging 5
Alarm message for end user by voice clip No
Voice guide for end user No
SMS out (device >> phone) Yes
SMS in (phone >> device) Yes
Operation of SECOLINK PRO using SMS services:
Android plain text
iPhone plain text
Number of recipients for internet messaging using app SECOLINK PRO 10
Requirements for online system control using the SECOLINK PRO app the
• system user must create an account in the ALARMSERVER.NET cloud and register the product by entering the product identification number "BI";
• the online service must be activated for the system4;
• the system requires a user SIM card with 10 - 20 MB of data per month.
Push notifications Yes
Reporting to Central Monitoring Station (CMS) Yes
Reporting to CMS format CID by GPRS/LTE Cat-M1
Reporting protocols for CMS E2 (Enigma), FIBRO (Sur-gard), CSV (Patriot), SIA
Compatible with SG-SYSTEM II , III IP card Yes
Rated voltage of power supply (AC) ~18 - 20 V
Minimum AC voltage ~16 V
(note: ~16 V input voltage lets control panel to generate max 0,5 A output current)
Maximum AC voltage ~22
(Note: higher than ~22 V voltage can damage control panel)
Maximum long term output current of control panel (I+AUX + I+BELL + I Battery charge) ≤0,7 A
Maximum current of slow blowing fuse used in primary AC 250 mA
Maximum AC power consumption 150 mA
Minimum voltage on +AUX, +BELL outputs 12 V
Maximum voltage on +AUX, +BELL outputs 13,9 V
Maximum current out of +AUX +0,5 A
Maximum current out of +BELL +2 A
Maximum current into -PGM1 -0,15 A
Maximum current into -PGM2 -0,15 A
Short circuit, overload protection of +BELL, +AUX Electronic
Battery charge, +BELL, +AUX current measurement Yes
Failed (waste) backup battery disconnection Yes
Maximum battery charging current +0,2 A
Maximum current of fast blowing fuse used in battery circuit 3,15 A
Control panel disconnect battery when it’s voltage less than 9,5 V
Operational compliance EN50131, Grade2
Recommended backup battery 12 V, 2,2 - 7Ah
Overall dimensions W x H in mm 145 x 77
Environmental compliance ROHS
Operating temperature From -10oC up to +50oC
Remote programming of control panel settings Yes