Products catalog

S16eT GSM alarm panel with integrated SIM card (eSIM)

  • S16eT GSM alarm panel with integrated SIM card (eSIM)

    Code: 03411
  • Rich of features S16 control panel fully meets the needs of installations up to 16 zones. Integration of S16 hardware with MASCAD PRO online setup software makes mounting of modular alarm system easy and fast. Both models are with free GSM communication. No more contract with GSM provider. Plug & Play cellular communication within 60 seconds.
    Specification


    On-board wired zones 5/10 (doubling)
    2-wire smoke detector input 1
    On-board wireless zones 16
    Maximum zones in system 16
    On-board PGM 3
    Maximum PGM in system 16
    User + installer codes 31+1
    Duress code Yes
    Defaulting user code Yes
    Key switch zone Yes
    Partitions 4
    "Shared" partition (common area) Yes
    System timers 16
    Maximum keypads/modules in system 3
    Keypad compatibility All SECOLINK keypads
    Event log buffer 256 (with keypad 512)
    Interface with transmitters and communicators of other manufacturers -
    Data bus protocol KRBUS
    "Roller" detector type Yes
    "Vibration" detector type Yes
    "Vibration" zone speed (sensitivity) 0.01 - 0.25 sec.
    Normal zone speed (sensitivity) 0.1 - 2.5 sec.
    Zone loop (detector) type NC, NO, NC/EOL, NO/EOL, NC/DEOL, NO/DEOL, Vibration, Roller, Wireless
    Arming mode Away, Max Away, Night, Stay.
    Embedded-SIM (eSIM) Yes
    S16eT - eSIM is working throughout the European Union;
    Reporting to Central Monitoring Station (CMS) Yes
    (There are additional conditions. Contact CMS company)
    Reporting to CMS format CID by GPRS/LTE Cat-M1
    Reporting protocols for CMS E2 (Enigma), FIBRO (Sur-gard), CSV (Patriot), SIA
    Compatible with SG-SYSTEM II , III IP card Yes
    Maximum load and electrical characteristics
    Rated voltage of power supply (AC) ~18 - 20 V
    Minimum AC voltage
    (note: ~16 V input voltage lets control panel to generate max 0,5 A output current) ~16 V
    Maximum AC voltage
    (Note: higher than ~22 V voltage can damage control panel) ~22
    Maximum long term output current of control panel (I+AUX + I+BELL + IBattery charge) ≤0,7 A
    Maximum current of slow blowing fuse used in primary AC 250 mA
    Maximum AC power consumption 150 mA
    Minimum voltage on +AUX, +BELL outputs 12 V
    Maximum voltage on +AUX, +BELL outputs 13,9 V
    Maximum current out of +AUX +0,5 A
    Maximum current out of +BELL +2 A
    Maximum current into -PGM1 -0,15 A
    Maximum current into -PGM2 -0,15 A
    Short circuit, overload protection of +BELL, +AUX Electronic
    Battery charge, +BELL, +AUX current measurement Yes
    Failed (waste) backup battery disconnection Yes
    Maximum battery charging current +0,2 A
    Maximum current of fast blowing fuse used in battery circuit 3,15 A
    Control panel disconnect battery when it’s voltage less than 9,5 V
    Operational compliance EN50131, Grade2
    Recommended backup battery 12 V, 2,2 - 7Ah
    Overall dimensions W x H in mm 145 x 77
    Environmental compliance ROHS
    Operating temperature From -10oC up to +50oC
    Remote programming of control panel settings Yes
    Interface with PC USB micro-B