S16eT GSM alarm panel with integrated SIM card (eSIM)
-
Rich of features S16 control panel fully meets the needs of installations up to 16 zones. Integration of S16 hardware with MASCAD PRO online setup software makes mounting of modular alarm system easy and fast. Both models are with free GSM communication. No more contract with GSM provider. Plug & Play cellular communication within 60 seconds.
Specification
On-board wired zones 5/10 (doubling)
2-wire smoke detector input 1
On-board wireless zones 16
Maximum zones in system 16
On-board PGM 3
Maximum PGM in system 16
User + installer codes 31+1
Duress code Yes
Defaulting user code Yes
Key switch zone Yes
Partitions 4
"Shared" partition (common area) Yes
System timers 16
Maximum keypads/modules in system 3
Keypad compatibility All SECOLINK keypads
Event log buffer 256 (with keypad 512)
Interface with transmitters and communicators of other manufacturers -
Data bus protocol KRBUS
"Roller" detector type Yes
"Vibration" detector type Yes
"Vibration" zone speed (sensitivity) 0.01 - 0.25 sec.
Normal zone speed (sensitivity) 0.1 - 2.5 sec.
Zone loop (detector) type NC, NO, NC/EOL, NO/EOL, NC/DEOL, NO/DEOL, Vibration, Roller, Wireless
Arming mode Away, Max Away, Night, Stay.
Embedded-SIM (eSIM) Yes
S16eT - eSIM is working throughout the European Union;
Reporting to Central Monitoring Station (CMS) Yes
(There are additional conditions. Contact CMS company)
Reporting to CMS format CID by GPRS/LTE Cat-M1
Reporting protocols for CMS E2 (Enigma), FIBRO (Sur-gard), CSV (Patriot), SIA
Compatible with SG-SYSTEM II , III IP card Yes
Maximum load and electrical characteristics
Rated voltage of power supply (AC) ~18 - 20 V
Minimum AC voltage
(note: ~16 V input voltage lets control panel to generate max 0,5 A output current) ~16 V
Maximum AC voltage
(Note: higher than ~22 V voltage can damage control panel) ~22
Maximum long term output current of control panel (I+AUX + I+BELL + IBattery charge) ≤0,7 A
Maximum current of slow blowing fuse used in primary AC 250 mA
Maximum AC power consumption 150 mA
Minimum voltage on +AUX, +BELL outputs 12 V
Maximum voltage on +AUX, +BELL outputs 13,9 V
Maximum current out of +AUX +0,5 A
Maximum current out of +BELL +2 A
Maximum current into -PGM1 -0,15 A
Maximum current into -PGM2 -0,15 A
Short circuit, overload protection of +BELL, +AUX Electronic
Battery charge, +BELL, +AUX current measurement Yes
Failed (waste) backup battery disconnection Yes
Maximum battery charging current +0,2 A
Maximum current of fast blowing fuse used in battery circuit 3,15 A
Control panel disconnect battery when it’s voltage less than 9,5 V
Operational compliance EN50131, Grade2
Recommended backup battery 12 V, 2,2 - 7Ah
Overall dimensions W x H in mm 145 x 77
Environmental compliance ROHS
Operating temperature From -10oC up to +50oC
Remote programming of control panel settings Yes
Interface with PC USB micro-B